Description:
LZCT-11 current transformer/CT,the secondary windings are full-enclosed in the flame retardant plastic shells, primary bushing or cable can pass through the inner hole, bottom has installation inserts for fixation. It is simple and shortcut, is suitable for measuring current, signal collection and protective relaying in the power system with the rated voltage 11kV of bushing or cable ect.
Technical Data:
1. Rated secondary current: 5A or 1A
2. Power frequency withstand voltage: 3kV
3. Rated frequency: 50/60Hz
4. Installation site: Indoor
5.Technical standard: IEC 60044-1:2003, IEC 61869-1&2
Outline Drawing
Specification
Note: Upon request we are glad to offer transformers according to other technical specs.
Sincerely yours,
------------------------------
Becky Wang (Manufacturer of LV&MV CT PT Suppliers)
Shenzhen Chuangyin Technology Co.,Ltd. (Website:www.chuangy.com)
Add:1st Floor,B Block,Jiada R&D Building,5# Song Pingshan Road,Shenzen High-tech Industrial Park,Nanshan,Shenzhen,China
Tel: + 86-755-86000302 Cell Phone: + 86-15889623648
LZCT-11 current transformer/CT,the secondary windings are full-enclosed in the flame retardant plastic shells, primary bushing or cable can pass through the inner hole, bottom has installation inserts for fixation. It is simple and shortcut, is suitable for measuring current, signal collection and protective relaying in the power system with the rated voltage 11kV of bushing or cable ect.
Technical Data:
1. Rated secondary current: 5A or 1A
2. Power frequency withstand voltage: 3kV
3. Rated frequency: 50/60Hz
4. Installation site: Indoor
5.Technical standard: IEC 60044-1:2003, IEC 61869-1&2
Outline Drawing
Specification
MODEL | LZCT1-11C | LZCT1-11P | LZCT1-11CP | ||||||
Purpose | Measuring Current Transformer | Protective Current Transformer | Double Winding CT | ||||||
Rated Primary Voltage(kV) | Accuracy Class and Rated burden(VA) | ||||||||
0.2 | 0.5 | 1 | 10P10 | 10P5 | 0.2 | 0.5 | 10P10 | 10P5 | |
50 |
|
|
1 |
|
|
|
|
|
|
75 |
|
1 | 1.5 |
|
|
|
|
|
|
100 |
|
2.5 | 5 |
|
2 |
|
1 |
|
|
200 |
|
5 | 5 | 1.5 | 2.5 |
|
2.5 |
|
|
300 | 2.5 | 5 |
|
2.5 |
|
1.5 | 2.5 |
|
2.5 |
400 | 5 | 7.5 |
|
3.75 |
|
2.5 | 5 |
|
2.5 |
500 | 5 | 10 |
|
5 |
|
2.5 | 5 | 2 | 3.75 |
600 | 5 | 10 |
|
5 |
|
3.75 | 7.5 | 2.5 | 5 |
MODEL | LZCT2-11C | LZCT2-11P | LZCT2-11CP | ||||||
Purpose | Measuring Current Transformer | Protective Current Transformer | Double Winding CT | ||||||
Rated Primary Voltage(kV) | Accuracy Class and Rated burden(VA) COS=0.8 |
||||||||
0.2 | 0.5 | 1 | 10P10 | 10P5 | 0.2 | 0.5 | 10P10 | 10P5 | |
30 |
|
|
1.5 |
|
|
|
|
|
|
50 |
|
1.5 | 2.5 |
|
1.5 |
|
|
|
|
75 |
|
2.5 | 5 |
|
2.5 |
|
1.5 |
|
|
100 |
|
2.5 | 5 |
|
3.75 |
|
2.5 |
|
2 |
200 | 2.5 | 5 | 7.5 |
3.75 | 5 |
|
3.75 |
1.5 |
2.5 |
300 | 5 | 7.5 |
|
5 |
|
2.5 | 5 |
2.5 |
|
400 | 7.5 | 10 |
|
7.5 |
|
5 | 7.5 | 3.75 |
|
500 | 10 | 15 |
|
10 |
|
5 | 10 | 5 |
|
600 | 10 | 15 |
|
10 |
|
5 | 10 | 5 |
|
Note: Upon request we are glad to offer transformers according to other technical specs.
Sincerely yours,
------------------------------
Becky Wang (Manufacturer of LV&MV CT PT Suppliers)
Shenzhen Chuangyin Technology Co.,Ltd. (Website:www.chuangy.com)
Add:1st Floor,B Block,Jiada R&D Building,5# Song Pingshan Road,Shenzen High-tech Industrial Park,Nanshan,Shenzhen,China